Infinity Vision Solution
HVAC ← Back

HVAC Design • VRV/VRF • Chillers • IAQ

Comfort cooling से लेकर mission-critical environments तक — हम load calculations, equipment selection, ducting, controls, commissioning और TAB (Testing, Adjusting, Balancing) end-to-end deliver करते हैं।

Overview
Ventilation & IAQ
VRV/VRF Systems
Chillers & AHU
Ducting & Controls
Commissioning & TAB
Energy Audit & Retrofit
Comparison

Overview

हम HVAC को lifecycle दृष्टि से design करते हैं — heat load (ASHRAE tables), equipment COP/EER, diversity factor, fresh air code compliance, acoustics, controls integration और maintainability पर फोकस रहता है।

ASHRAE / ISHRAE NBC/ECBC Ready Low Noise Design BMS Integration

Design Highlights

  • Room-wise heat load, infiltration, ventilation (CFM) और sensible/latent balance.
  • Equipment selection by COP/ IPLV, part-load strategy और redundancy (N+1).
  • Hydronic/ refrigerant piping sizing, pump head calc, expansion & safety.
  • Acoustic treatment, vibration isolation, condensate management.

Ventilation & IAQ

Fresh air (O.A.) with heat recovery (HRV/ERV), filtration (MERV 8–13/HEPA), pressurization & exhaust balance for healthy interiors.

HRV/ERV HEPA/MERV CO₂ Control Pressurization

Key Points

  • Demand-controlled ventilation via CO₂/TVOC sensors.
  • Toilet/Kitchen/Car-park exhaust with make-up air & VFD control.
  • Positive/negative pressure rooms as per application (labs, OT, kitchens).

VRV/VRF Systems

Inverter-driven multi-split with long piping runs, simultaneous heat/cool (heat recovery) options, zoning flexibility और excellent part-load efficiency.

Inverter Scroll Heat Recovery Long Piping Zoning

Design & Safety

  • Refrigerant piping sizing, oil traps, elevation checks, leak detection (R-410A/ R-32).
  • Refnet/header layout, sub-cooling, condensate strategy.
  • Third-party controls / centralized BMS integration (BACnet/Modbus).

Chillers & AHU Plants

Air/Water-cooled chillers, primary-secondary pumping, VFDs, AHU/FAHU with coil selection — large buildings/industrial के लिए best choice.

Air/Water Cooled Primary-Secondary VFD Pumps FAHU/AHU

Hydronics & Plant Room

  • P&ID, pipe sizing, pump head calc, expansion tank & PRV selection.
  • Cooling towers (for water-cooled), approach & cycles-of-concentration.
  • Plate heat exchanger, bypass & differential pressure control.

Ducting & Controls (BMS)

SMACNA-based duct design, leakage class, balancing dampers; BMS/IoT driven temperature, humidity & airflow control.

SMACNA VAV/CAV Fire/Smoke Dampers BMS/IoT

Key Elements

  • VAV boxes, reheat coils, anti-sweat insulation, acoustic lining.
  • Motorized fire/smoke dampers with interlocks.
  • DDC controllers, BACnet/IP integration, trend logs & alarms.

Commissioning & TAB

Method statements, ITP, pre-functional/functional tests, air/water balancing और O&M training के साथ project handover.

ITP/Checklists Water/Air Balance Acoustic Tests O&M Packs

Deliverables

  • As-built drawings (GA, Ducting, Piping), control architecture & IO list.
  • Balancing reports, instrument calibration, test certificates.
  • Training, O&M manuals, spares lists & warranty documentation.

Energy Audit & Retrofit

Existing systems में energy saving — VFDs, heat recovery, EC fans, high-efficiency coils, control optimization & IAQ upgrades.

VFD Retrofits Heat Recovery EC Fans IAQ Upgrade

Typical Savings

  • Part-load optimization (VRF/Chiller sequencing).
  • Demand-controlled ventilation (CO₂-based), economizer cycles.
  • Water-side optimization: ΔT reset, pump VFDs, tower fan VFDs.

System Comparison

ParameterDX / SplitVRV/VRFChiller + AHU
CapexLowMediumHigh
Opex / EfficiencyMediumHigh (part-load)High (with VFD/IPLV)
ScalabilityLowHigh (zoning)Very High (large sites)
ControlsBasicAdvancedAdvanced/BMS
Best ForSmall offices/retailMulti-storey, hotelsMalls, campuses, plants
RedundancyUnit levelModule levelN+1 plant level
IAQ UpgradesLimitedGoodExcellent (AHU/FAHU)

Final selection load profile, zoning, capex/opex, maintainability और future expansion पर depend करता है.